{"id":1128,"date":"2024-09-26T14:13:13","date_gmt":"2024-09-26T14:13:13","guid":{"rendered":"https:\/\/connectwin.egis-group.com\/fiche-reference\/modeling-and-simulation-of-the-structural-behavior-of-a-nuclear-power-plant\/"},"modified":"2025-02-03T10:50:58","modified_gmt":"2025-02-03T10:50:58","slug":"modeling-and-simulation-of-the-structural-behavior-of-a-nuclear-power-plant","status":"publish","type":"fiche-reference","link":"https:\/\/connectwin.egis-group.com\/en\/fiche-reference\/modeling-and-simulation-of-the-structural-behavior-of-a-nuclear-power-plant\/","title":{"rendered":"Simulation of the structural behavior of a nuclear power plant"},"content":{"rendered":"<!--themify_builder_content-->\n<div id=\"themify_builder_content-1128\" data-postid=\"1128\" class=\"themify_builder_content themify_builder_content-1128 themify_builder tf_clear\">\n                    <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_m6gk886 tb_first tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_2f7z887 first\">\n                    <!-- module plain text -->\n<div  class=\"module module-plain-text tb_tuvn91 \" data-lazy=\"1\">\n        <div class=\"tb_text_wrap\">\n    Extending the service life of existing nuclear power plants is a low-carbon solution to today&#8217;s energy challenges. In this context, it is crucial to assess the structural strength of power plants by accurately modeling the mechanical phenomena of reinforced concrete. There are two key aspects to the extension of their lifespan: the state of cracking of reinforced concrete and the behavior of the structure in response to earthquakes.  \n\n    <\/div>\n<\/div>\n<!-- \/module plain text --><!-- module plain text -->\n<div  class=\"module module-plain-text tb_g9c3396 \" data-lazy=\"1\">\n        <div class=\"tb_text_wrap\">\n    Egis, in partnership with industrial and academic research laboratories, has developed a digital twin of the mechanical structure, enabling the most accurate possible detailed analysis of the influence of these physical phenomena on the existing civil engineering structure.\n    <\/div>\n<\/div>\n<!-- \/module plain text --><!-- module plain text -->\n<div  class=\"module module-plain-text tb_g5zg875 \" data-lazy=\"1\">\n        <div class=\"tb_text_wrap\">\n    This numerical twin uses a multi-scale analytical method to describe the evolution of cracks, concrete, concrete damage, rebar delamination and relative slippage between concrete and rebar. This solution reproduces, at the global scale of the structure, the impact and evolution of local mechanical phenomena in reinforced concrete. What&#8217;s more, this digital twin can be enhanced with real-time measurements to simulate the impact of observed phenomena on the actual building and predict the evolution of the structure&#8217;s state.  \n\n    <\/div>\n<\/div>\n<!-- \/module plain text -->        <\/div>\n                        <\/div>\n        <\/div>\n                        <div  data-lazy=\"1\" class=\"module_row themify_builder_row tb_771g1 tf_w\">\n                        <div class=\"row_inner col_align_top tb_col_count_2 tf_box tf_rel\">\n                        <div  data-lazy=\"1\" class=\"module_column tb-column col4-2 tb_r1hf1 first\">\n                    <!-- module image -->\n<div  class=\"module module-image tb_y0fu754 image-top   tf_mw\" data-lazy=\"1\">\n        <div class=\"image-wrap tf_rel tf_mw\">\n            <img decoding=\"async\" width=\"845\" height=\"411\" src=\"https:\/\/connectwin.egis-group.com\/wp-content\/uploads\/2024\/09\/nuclear-model-structure4.jpg\" class=\"wp-post-image wp-image-1127\" title=\"nuclear-model-structure4\" alt=\"nuclear-model-structure4\" srcset=\"https:\/\/connectwin.egis-group.com\/wp-content\/uploads\/2024\/09\/nuclear-model-structure4.jpg 845w, https:\/\/connectwin.egis-group.com\/wp-content\/uploads\/2024\/09\/nuclear-model-structure4-300x146.jpg 300w, https:\/\/connectwin.egis-group.com\/wp-content\/uploads\/2024\/09\/nuclear-model-structure4-768x374.jpg 768w\" sizes=\"(max-width: 845px) 100vw, 845px\" \/>    \n        <\/div>\n    <!-- \/image-wrap -->\n    \n        <\/div>\n<!-- \/module image -->        <\/div>\n                    <div  data-lazy=\"1\" class=\"module_column tb-column col4-2 tb_k0z91 last\">\n                    <!-- module image -->\n<div  class=\"module module-image tb_p9z0528 image-top   tf_mw\" data-lazy=\"1\">\n        <div class=\"image-wrap tf_rel tf_mw\">\n            <img decoding=\"async\" width=\"845\" height=\"411\" src=\"https:\/\/connectwin.egis-group.com\/wp-content\/uploads\/2024\/09\/nuclear-model-structure3.jpg\" class=\"wp-post-image wp-image-1125\" title=\"nuclear-model-structure3\" alt=\"nuclear-model-structure3\" srcset=\"https:\/\/connectwin.egis-group.com\/wp-content\/uploads\/2024\/09\/nuclear-model-structure3.jpg 845w, https:\/\/connectwin.egis-group.com\/wp-content\/uploads\/2024\/09\/nuclear-model-structure3-300x146.jpg 300w, https:\/\/connectwin.egis-group.com\/wp-content\/uploads\/2024\/09\/nuclear-model-structure3-768x374.jpg 768w\" sizes=\"(max-width: 845px) 100vw, 845px\" \/>    \n        <\/div>\n    <!-- \/image-wrap -->\n    \n        <\/div>\n<!-- \/module image -->        <\/div>\n                        <\/div>\n        <\/div>\n        <\/div>\n<!--\/themify_builder_content-->","protected":false},"featured_media":1123,"template":"","categorie-fiche":[35],"class_list":["post-1128","fiche-reference","type-fiche-reference","status-publish","has-post-thumbnail","hentry","categorie-fiche-nuclear","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author",""],"acf":[],"_links":{"self":[{"href":"https:\/\/connectwin.egis-group.com\/en\/wp-json\/wp\/v2\/fiche-reference\/1128","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/connectwin.egis-group.com\/en\/wp-json\/wp\/v2\/fiche-reference"}],"about":[{"href":"https:\/\/connectwin.egis-group.com\/en\/wp-json\/wp\/v2\/types\/fiche-reference"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/connectwin.egis-group.com\/en\/wp-json\/wp\/v2\/media\/1123"}],"wp:attachment":[{"href":"https:\/\/connectwin.egis-group.com\/en\/wp-json\/wp\/v2\/media?parent=1128"}],"wp:term":[{"taxonomy":"categorie-fiche","embeddable":true,"href":"https:\/\/connectwin.egis-group.com\/en\/wp-json\/wp\/v2\/categorie-fiche?post=1128"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}